Aqua HealthWater Purification
HomeShopInstallationsPurificationWhy us
ENاردوسنڌيپښتو
AccountGet a Quote
Aqua HealthWater Purification

Pure water for healthy homes and honest industry — RO plants, filtration systems and genuine parts, installed and serviced with care.

Shop

  • Domestic RO
  • Whole-House Filtration
  • Industrial & Commercial RO
  • Filters & Parts
  • Accessories

Company

  • Installations
  • 7-stage purification
  • Why Aqua Health
  • Get a quote
  • Returns & warranty
  • Shipping & delivery
  • Terms of service
  • Privacy policy
  • Contact us

Visit us

  • 📍 Aqua Health Store, Main Boulevard, Multan
  • 📞0345.510.3157
  • ✉️hello@aquahealth.pk
  • 🕒 Mon–Sat, 9 am – 8 pm
© 2026 Aqua Health. All rights reserved.Designed and Developed by iqaai.com
Aqua HealthWater Purification
HomeShopInstallationsPurificationWhy us
ENاردوسنڌيپښتو
AccountGet a Quote
Home/Shop/Commercial RO Plants/Commercial Reverse Osmosis (RO) Water Purification Plant 1000 LPH
Commercial RO PlantsIn stock — installs within 24h

Commercial Reverse Osmosis (RO) Water Purification Plant 1000 LPH

6-Stage RO System • 1000 LPH Output • For Commercial & Industrial Use

Price on request

Final total — options, selected quantity, pack and bundle included

Quantity
1
Get a quote on WhatsApp →
DeliveryAt checkout
ReturnsPolicy applies
Payment

Product information

Product description

INDUSTRIAL WATER TREATMENT EQUIPMENT
RO PLANT
1000 L/H
1 ton per hour · pretreatment + single-pass reverse osmosis · skid mounted · automatic
 
OUTPUT
1000 L/H
PER 24 HOURS
24 m³
SALT REJECTION
≥ 97%
MEMBRANE
0.0001 µm
 
MODEL · RO-1000
HS CODE · 8421219990
WARRANTY · 12 MONTHS  |  FEED TEMP · 10-40°C
OEM / ODM WELCOME
PROCESS FLOW
 
THE TREATMENT TRAIN
Pretreatment protects the membrane. Only the membrane removes dissolved salts. The reading in each row shows where the real drop happens — shown on 800 ppm well water. Vessels are sized for roughly 2 m³/h of feed.
RAW WATER IN  ↓  800 ppm TDS
01
IN
RAW WATER TANK
Buffer volume and float control, so the feed pump never runs dry. Plan on at least 2 m³/h of available supply.
TDS 800 ppm
02
SF
QUARTZ SAND FILTER
Strips suspended solids, silt and turbidity down to about 20 µm. Backwash valve fitted as standard.
TDS 800 ppm · TURBIDITY DOWN
03
AC
ACTIVATED CARBON FILTER
Adsorbs free chlorine, organics, colour and odour. Chlorine destroys RO membranes, so this stage is not optional on municipal feed.
TDS 800 ppm · CHLORINE TO ZERO
04
SO
WATER SOFTENER (OPTIONAL)
Ion exchange removes calcium and magnesium so the membrane does not scale. Recommended above 200 ppm hardness.
TDS 800 ppm · HARDNESS DOWN
05
PP
5 µm SECURITY CARTRIDGE
Multi-cartridge stainless housing before the high-pressure pump. Cheap to change, protects everything downstream.
TDS 800 ppm · SDI DOWN
06
RO
REVERSE OSMOSIS MEMBRANES
A 2.2 kW vertical multistage pump drives the feed across four 4040 brackish-water membranes at 10-15 bar in a 2:2 array. This is the only stage that removes dissolved salt.
TDS OUT ≤ 24 ppm · 97% REJECTED
07
UV
UV STERILIZER & TANK
254 nm disinfection on the outlet, then storage in the pure water tank ready for use.
PRODUCT WATER ≤ 24 ppm
PURE WATER OUT  ↓  ≤ 24 ppm TDS · 1000 L/H
» Output TDS scales with your feed water. 97% rejection applies to your water, not ours.
» At 50-60% recovery the unit draws 1.7-2.0 m³/h of feed per 1 m³/h of permeate.
» Softener and UV stages are specified per water report.
» An online conductivity meter reads permeate quality continuously.
BEFORE YOU ORDER
 
SEND US THREE NUMBERS
An RO skid is configured against your feed water, not picked off a shelf. These three figures let our engineers confirm membrane count, pump head and recovery rate before anything is built.
01 · FEED TDS
In ppm or µS/cm
Under 2,000 ppm runs as the standard brackish-water configuration. Higher values change membrane type and pump selection.
 
02 · SOURCE AND SUPPLY RATE
Well, municipal or river
This decides how much pretreatment you need. Confirm your source can sustain about 2 m³/h — an undersized borehole is the usual reason a 1 T/H plant underperforms.
 
03 · POWER SUPPLY
Voltage, phase, frequency
Normally built for 380 V three-phase, 50 or 60 Hz. Single-phase 220 V is possible on request. Tell us and the panel ships wired for your grid.
No water report? Send a sample result from any local laboratory, or tell us the region and the application — we have configured systems for buyers in over 100 countries and can start from comparable water.
TECHNICAL DATA · RO-1000
 
SPECIFICATIONS
PERFORMANCE
Permeate capacity1000 L/H
Daily output at 24 h24 m³
Required feed flow1.7-2.0 m³/h
Desalination rate≥ 97%
Recovery rate50-60%
Membrane pore size0.0001 µm
Operating pressure10-15 bar
Feed water temperature10-40 °C
Recommended feed TDS< 2,000 ppm
CORE COMPONENTS
High-pressure pumpVertical multistage 2.2 kW
RO membranes4 × 4040 brackish water
Membrane array2:2, FRP vessels
Pretreatment vesselsStainless steel / FRP
Security filter5 µm PP, SS housing
FrameSS304 skid
PipingUPVC / SS304
CONTROL & INSTRUMENTS
Operation modeFully automatic
Water quality monitoringOnline conductivity meter
Pressure indicationInlet, membrane, concentrate
Flow indicationPermeate + concentrate
ProtectionHigh / low pressure cut-out
Fault handlingAlarm and indicator per fault
Auto flushOn start and stop
Power supply380 V 3-phase, 50-60 Hz
SHIPPING & COMMERCIAL
Net weight240 kg
Gross weight350 kg
Package volume2.1 CBM
PackingFilm + wooden case
Machinery test reportProvided
Warranty12 months
Place of originZhengzhou, Henan, China
HS code8421219990
Annual production800 sets / year
HOW IT IS BUILT
 
SIX THINGS THAT KEEP IT RUNNING
MEMBRANE LIFE
HIGH REJECTION, STABLE OVER TIME
Correct pretreatment keeps flux stable instead of decaying, so you clean on a schedule rather than every few weeks. At 1 T/H that difference is real money in downtime.
 
FOOTPRINT
ONE SKID, FOUR CONNECTIONS
Pretreatment, pump, membranes and panel arrive assembled on a single frame. Connect feed, drain, permeate and power.
 
PUMP PROTECTION
HIGH AND LOW PRESSURE CUT-OUT
The pump stops if inlet pressure drops or membrane pressure spikes — the most common cause of field failures, guarded here in hardware.
 
DIAGNOSTICS
FAULTS NAME THEMSELVES
Each protection trip lights its own indicator, so an operator can tell a low-inlet trip from an overpressure trip without a meter.
 
WATER QUALITY
CONDUCTIVITY READ CONTINUOUSLY
Rising conductivity is the early warning that membranes need cleaning. You see it before your product does.
 
SERVICE
DESIGN, BUILD, INSTALL
17 years producing water treatment equipment, with engineers carrying 24 years of field experience. One supplier from drawing to spare parts.
TYPICAL DUTY
 
WHERE A 1000 L/H UNIT FITS
BOTTLING PLANTS
Commercial drinking water production, 19 L jar lines and small PET bottling.
 
FOOD & BEVERAGE
Beverage blending, ice plants, dairy, bakery and brewing feed water.
 
PHARMA & LABORATORY
Purified water pretreatment ahead of EDI, DI or second-pass polishing.
 
INDUSTRY & BUILDINGS
Boiler make-up, cooling towers, electroplating rinse, cosmetics, hotels and hospitals.
PACKING & DELIVERY
 
WHAT ARRIVES
IN THE CRATE
▪  Assembled RO skid with pretreatment vessels and four membrane housings
▪  Membranes fitted, wet-tested and flushed before dispatch
▪  Control panel wired to your voltage and frequency
▪  Machinery test report and water quality result
▪  Installation drawing, operation manual and commissioning checklist
▪  Spare cartridge set and basic tool kit
EXPORT PACKING
Every unit is wrapped in protective plastic film, corner-protected and crated in a fumigation-free export wooden case. Vessels are strapped to the skid so nothing shifts in transit.
Shipping volume is 2.1 CBM at 350 kg gross, comfortably inside LCL sea freight, with air freight possible for urgent orders. We ship EXW, FOB or CIF and can consolidate tanks, filling lines or spare membranes into the same container.
OEM and ODM accepted: your brand plate, panel layout, colour, vessel material and stage configuration.
QUESTIONS BUYERS ASK FIRST
 
FAQ
Q. Will 1000 L/H be enough for my plant?
Size against your peak draw, not your average. Running 24 hours gives 24 m³ per day; an eight-hour shift gives 8 m³, roughly 400 nineteen-litre jars. If demand sits close to the limit, add a larger pure water tank rather than a larger skid — storage is far cheaper than capacity.
Q. How much raw water does it consume?
At 50-60% recovery the unit needs about 1.7 to 2.0 m³/h of feed to produce 1 m³/h of permeate. The rest leaves as concentrate, which many buyers reuse for washing, cooling or irrigation. Confirm your supply can sustain that flow before ordering.
Q. What TDS can the feed water be?
The standard configuration is built for brackish feed under 2,000 ppm. Between 2,000 and 10,000 ppm we change membrane type and pump head. Seawater at roughly 35,000 ppm needs a different system entirely — send your figure and we will quote the right one.
Q. How often do membranes and cartridges need changing?
The 5 µm cartridges are consumables, typically every one to three months depending on feed turbidity. RO membranes last two to three years on properly pretreated water. Rising permeate conductivity or falling flow tells you when cleaning is due.
Q. Does it produce drinking water directly?
RO permeate meets drinking water standards for dissolved solids, and the UV stage handles disinfection. For bottling you would normally add remineralisation or ozone depending on local regulations — we can include either stage.
Q. Are spare parts available after installation?
Yes. Membranes, cartridges, pumps and control components are stocked and shipped worldwide. Installation and commissioning support is provided by video call, with drawings and a written checklist supplied with the machine.
Q. What is the lead time?
Standard configurations ship in 7 to 15 working days after order confirmation. Customised stage layouts, non-standard voltage or OEM branding typically add one to two weeks.
NEXT STEP
GET IT CONFIGURED FOR YOUR WATER
Message us with your feed TDS, water source and power supply. You will get a stage-by-stage configuration, the expected permeate quality and a delivered price. Other capacities available from 250 L/H to 20 m³/h.
ASK A QUESTION →

Keep browsing

You may also like

At checkout

A 6-stage commercial reverse osmosis (RO) water purification plant rated for 1000 liters per hour (LPH) of purified output; sized for continuous, higher-volume use in factories, offices, restaurants, bottled-water operations, and other commercial or institutional settings where a household RO unit isn't enough. The 6-stage layout is the standard commercial configuration: sediment and carbon pre-filtration ahead of the RO membrane stage, with a post-carbon polishing stage after it. No price or physical specifications (weight, dimensions, pump/electrical rating) are set yet; none were provided, and this is a large enough system that guessing at them isn't a reasonable substitute for the real sourced numbers. Fill those in from the actual unit before publishing.

500 LPH Commercial Reverse Osmosis (RO) Water Purification Plant
Commercial RO Plants

500 LPH Commercial Reverse Osmosis (RO) Water Purification Plant

Rs 450,000

6-stage Commercial Reverse Osmosis (RO) Water Purification Plant 500 LPH
Commercial RO Plants

6-stage Commercial Reverse Osmosis (RO) Water Purification Plant 500 LPH

Price on request

High Quality 250 L/H Small Water Purification System RO
Commercial RO Plants

High Quality 250 L/H Small Water Purification System RO

Price on request